IEC 61951-2: The full name is Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary sealed cells and batteries for portable applications – Part 2: Nickel-metal hydride batteries. It specifies marking, designation, dimensions, tests and requirements for secondary sealed nickel-metal hydride small prismatic, cylindrical and button cells and batteries, suitable for use in any orientation, for portable applications. It is the global standard.
Features
- Working voltage 1.0-1.4V.
- Eco-friendly, free from harmful heavy metals such as Hg, Cd and Pb.
- Stable flat discharge voltage performance.
- No memory effect.
- Long cycle life.
- Safer than Li-ion batteries; NiMH can pass the ATEX test for underground applications.
- Button shape.
Technical Specifications
Button Type
| Model | Nominal Capacity (mAh) | Nominal Voltage (V) | Dimensions (with tube) (±0.5mm) | Max. Charge (mA) | Max. Discharge (mA) | Weight (g) | |
|---|---|---|---|---|---|---|---|
| Diameter | Height | ||||||
| B20 | 20 | 1.2 | 11.6 | 3.1 | 4 | 10 | 1.7 |
| B40 | 40 | 1.2 | 11.6 | 5.4 | 8 | 20 | 2.0 |
| B80 | 80 | 1.2 | 15.2 | 6.1 | 16 | 40 | 3.2 |
| B110 | 110 | 1.2 | 15.2 | 7.7 | 11 | 60 | 3.6 |
| B160 | 160 | 1.2 | 25.6*14.1 | 5.7 | 32 | 80 | 5.8 |
| B250 | 250 | 1.2 | 25.2 | 6.4 | 50 | 125 | 10.0 |
| B330 | 330 | 1.2 | 25.2 | 8.5 | 33 | 66 | 12.5 |
| B9V | 160 | 1.2 | 27.0*16.0 | 49.0 | 32 | 80 | 44 |
Industrial NiMH chemistry charge reaction: Ni(OH)2 + M → NiOOH + MH.
Discharge reaction: NiOOH + MH → Ni(OH)2 + M.
Related product: telecom backup battery.
Applications
- Telecom equipment
- Emergency lights
- Smoke alarms
- Electric locks
Certifications
UL 2054: Household and Commercial Batteries. It is a safety standard covering household and commercial battery packs, electrical testing, and mechanical criteria. It evaluates primary and secondary batteries to minimize fire and explosion risks. It applies to multi-cell or single-cell battery packs used in consumer electronics, medical devices, and power tools. It is a compulsory certification for battery products exported to the United States and Canada, ensuring full compliance with local market access and safety regulations.
2014/35/EU: Directive 2014/35/EU, known as the Low Voltage Directive, sets common safety rules for electrical equipment in the European Union. The directive covers electrical equipment designed for use with a voltage rating of between 50 and 1000 volts for alternating current (AC) or between 75 and 1500 volts for direct current (DC). Importantly, it does not cover voltages within equipment. The directive does not cover components (broadly, this refers to individual electronic components).
RoHS 2.0 (2011/65/EU) restricts hazardous materials, specifically lead, cadmium, and mercury, in electrical goods.
User Manual
- Only use dedicated Ni-MH battery chargers. Do NOT charge the battery with lithium-ion or NiCd chargers.
- Never overcharge or reverse-charge the battery. Smart chargers with -ΔV detection and temperature protection are recommended.
- It is recommended to connect the cells in series to increase the operating voltage.
- A mild temperature rise during charging is normal. Stop charging immediately if the battery becomes overheated or swollen.
- Maintain the battery at 40%-60% state of charge (SoC) for long-term storage. Do not store it fully charged or fully depleted.
- Remove the batteries from the equipment if the device will not be used for an extended period.
- Store the batteries in a cool, dry and well-ventilated place at 5-25°C, away from direct sunlight, heat sources and humidity.
- Keep battery terminals clean and dry; moisture may cause leakage and terminal corrosion.
- If capacity decreases after long storage, perform 2-3 full charge-discharge cycles to restore performance.
- Replace the battery at the end of its cycle life or after severe capacity degradation.
FAQ
A: B20 20mAh, B40 40mAh, B80 80mAh, B110 110mAh, B160 160mAh, B250 250mAh and B330 330mAh, plus B9V at 160mAh, all at 1.2V nominal.
A: Max. charge current ranges from 4mA (B20) to 50mA (B250); max. discharge current ranges from 10mA (B20) to 125mA (B250), as listed per model in the table.
A: Use a dedicated Ni-MH charger with -ΔV detection and temperature protection; lithium-ion or NiCd chargers must not be used.
A: At 40%-60% state of charge in a cool, dry, well-ventilated place at 5-25°C, away from direct sunlight, heat sources and humidity.
A: UL 2054, IEC 61951-2, RoHS 2.0 (2011/65/EU) and 2014/35/EU.
Related Battery Products
Discover complementary products in our Li-Ion and energy storage lineup.
NIMH Cylindrical 1.2V 700-15000mAh Rechargeable Battery
NiMH cylindrical cells from AAA to F size, 1.2V and 700-15000mAh, with high-power, high-temperature, low-self-discharge and…
View Details
Li-ion High Capacity 3.6V 750-5000mAh Rechargeable Battery
Li-ion energy cells in ICR14500, INR18650, NCR18650, INR26650 and INR21700 sizes, 3.6V and 750-5000mAh, with 1000-2000…
View Details
Li-ion High Power 3.6V 1500-4500mAh Rechargeable Battery
Li-ion power cells INR18650P/R/H and INR21700R/P, 3.6V and 1500-4500mAh, with 1-3C charge and 3C-10C discharge for…
View Details
Li-ion Low Temp 3.6V 2000-4500mAh Rechargeable Battery
Li-ion low temperature cells INR18650L/A/M and INR21700A/B, 3.6V and 2000-4500mAh, discharging from -40°C to 60°C without…
View Details