Lighting battery application banner background
Li-ion · LiFePO4 · NiMH

Lighting Battery

High-reliability battery packs for emergency lighting, portable lamps, garden lights and 12V lighting systems. Custom configurations, fresh cells and certified safety protection for every application.

Built for Light

Key Features

Proven chemistries and pack designs for emergency, portable and outdoor lighting products.

No Memory Effect

NiMH cells deliver consistent capacity without the memory effect associated with older battery chemistries.

Emergency-Lighting Proven

NiMH packs are widely used in emergency lighting for their safety and high-temperature performance.

Broad Portable Coverage

Li-ion packs power torches, bicycle lights, garden lights and portable lamps for a fast-growing global market.

Custom Pack Design

Pack configurations are designed around your device, weight target, capacity requirement and enclosure.

Fresh Cells Only

We assemble packs with fresh cells to ensure full capacity, long operating time and excellent cycle life.

Integrated Protection

PCM protection guards against over-charge, over-discharge, over-current and short circuit.

Product Information

Lighting Battery Models

Select a battery model below to view its electrical specifications and operating limits.

Li-ion 18650 1S6P lighting battery pack
Battery TypeLi-ion 18650
Configuration1S6P (six parallel cells)
Nominal Voltage3.7V
ApplicationLED emergency light / portable lamp / garden lamp
Operating TemperatureCharging 0~45°C · Discharging -20~60°C
ProtectionOver-Charge / Over-Discharge / Over-Current / Short Circuit
LiFePO4 18650 1S1P lighting battery
Battery TypeLiFePO4 18650 1S1P
Nominal Voltage3.2V
Capacity1500mAh
Energy4.8Wh
Work Voltage Range2.5–3.65V
Cycle Life>2000 cycles (at 0.2C charge/discharge)
Operating TemperatureCharging 0~45°C · Discharging -20~60°C
ApplicationEmergency lights / wireless phones / telecom devices
ProtectionOver-Charge / Over-Discharge / Over-Current / Short Circuit
NiMH 18700 12V lighting battery pack
Battery TypeNiMH 18700
Nominal Voltage12V
Capacity4500mAh
Configuration10S1P (ten 1.2V cells)
Operating TemperatureCharging 0~45°C · Discharging -20~60°C
ApplicationEmergency lighting / portable lamps / backup lighting
ProtectionOver-Charge / Over-Discharge / Over-Current / Short Circuit
NiMH AA 6V emergency lighting battery pack
Battery TypeNi-MH AA Battery
Typical Voltage6V
Work Voltage Range5.0–7.0V
Capacity1600mAh / 1800mAh / 2000mAh
Applied Current<2A
Cycle Life>500 cycles (at 0.2C charge/discharge)
Sizemax. 14.8 × 51 × 73.0 mm
Applied Temperature0–70°C
ApplicationEmergency lighting / portable devices / broadcasting devices / handheld radio
More Configurations

Additional Cell Options

LiFePO4 26650 1S1P3.2V · 2.5Ah / 3.2Ah · 32.5 × 60.0 mm · >2000 cycles · emergency lights, wireless phones, telecom devices
NiMH A 4.8V4.8V · 2200mAh · 17.9 × 200 mm · >500 cycles · emergency light, high-temperature devices, LED lighting
Compliance

Certifications

Lighting battery packs are tested and certified to the following international safety and transport standards.

  • UL 2054
  • IEC 62133-2:2017
  • UN 38.3
  • MSDS
  • RoHS
  • (EU) 2023/1542
Standards Explained

Certification Details

A closer look at the standards our lighting batteries comply with.

IEC 62133-2:2017

Safety requirements for portable sealed secondary lithium cells and batteries containing non-acid electrolyte, under intended use and reasonably foreseeable misuse. It is the necessary certification for selling lithium batteries in the EU region and covers Li-ion cells and packs under 60 VDC.

UL 2054

Covers household and commercial batteries, including lithium rechargeable packs, against risks of fire, explosion and electric shock during normal use and foreseeable misuse.

UN 38.3

UN Manual of Tests and Criteria, Section 38.3. All lithium batteries shipped by air, sea or land must carry the relevant test report and certification. Li-ion cells and packs belong to UN3480; batteries installed in a device are packaged under UN3481.

(EU) 2023/1542 & RoHS

The EU New Battery Regulation defines battery categories and compliance duties across the battery lifecycle. RoHS 2.0 restricts lead, cadmium and mercury in electrical goods.

Safe Operation

User Manual

Important operating and safety instructions. Please read carefully before installation and use.

  1. 01

    Please use qualified equipment for battery charging and discharging, and follow the operating instructions strictly.

  2. 02

    The PCM of lithium rechargeable batteries provides over-charge and over-discharge safety protection. The applied device shall be configured with reasonable cut-off voltages according to the battery electrical parameters.

  3. 03

    Do not mix batteries of different models or batteries from different manufacturers.

  4. 04

    Do not combine new and old batteries for use.

  5. 05

    Do not short-circuit the positive and negative terminals with any metal conductors.

  6. 06

    Do not pierce, strike, trample, fold or violently impact the batteries with metal tools or by any other means.

  7. 07

    Do not place, charge or operate the batteries in vehicles or confined spaces where the ambient temperature may exceed 60°C.

  8. 08

    Do not reverse-charge the batteries.

  9. 09

    Do not disassemble or modify the battery, including its internal circuit structure.

  10. 10

    Do not use damaged batteries, including units with broken sealing edges, damaged outer PVC casings or electrolyte leakage.

  11. 11

    Do not immerse the battery in water or expose it to moisture.

  12. 12

    Do not use or store the battery near fire sources or heaters.